Image lead edge adjustment
50
01
Copy lead edge position adjustment (SPF/RSPF)
06
Paper off-center adjustment
10
Document off-center adjustment
12
Resist amount adjustment
51
02
SPF scanning position automatic adjustment
53
08
SPF scan position change-over setting
10
HSYNC output check
61
03
Shading check
63
01
SPF automatic correction
07
Self print
64
01
4. Contents of simulations
Main
Sub
Contents
code
code
Mirror scanning operation aging
01
06
Single paper feeder (SPF) aging
02
01
SPF sensor status display
02
Paper feed solenoid operation
06
01
check
Contents
When the [START] key is pressed, the mirror base performs A3 full scanning at the set magnification
ratio speed. During scanning, the set magnification ratio is displayed. After 3 seconds, the mirror
base performs full scanning again. During scanning, the set magnification ratio is displayed.
*
When the [START] key is pressed again, the ready lamp turns and remains off.
The DV replacement/OPC drum cartridge replacement lamp displays the status of the mirror
home position sensor. (The lamp lights up when the mirror is in the home position.)
During aging, the copy lamp lights up. When the [Interrupt] key is pressed, the operation is
interrupted if operating, and the machine goes into the sub code input standby mode.
When the [START] key is pressed, the set magnification ratio is acquired and document transport
operation of single surface is performed in the case of SPF or document transport operation of
duplex surfaces is performed. During operation, the LED on the display section corresponding to the
selected magnification ratio lights up, and the magnification ratio is displayed on the 7-seg display.
When the [Interrupt] key is pressed at that time, the machine goes to the sub code input standby
mode. When the [CA] key is pressed, the simulation is terminated.
(In order to receive the sensor change notification, the load must be decreased.)
The sensor status (ON/OFF) in the SPF can be checked with the following lamps.
When a sensor detects paper, it turns on. The open/close detection sensor turns on when the
machine is opened.
Display lamp
Toner supply lamp
Copier jam lamp
The DV replacement/OPC drum cartridge
replacement lamp
Paper empty lamp
SPF jam lamp
Manual paper feed lamp
Tray jam lamp
AE lamp
TEXT lamp
PHOTO lamp
When the [Interrupt] key is pressed, the machine goes to the sub code input standby mode.
When the [CA] key is pressed, the simulation is terminated.
When this simulation is executed, the sub code is displayed on the 7-seg LED and the lamp
corresponding to the solenoid lights up.
Select a solenoid with the tray select key (the lamp corresponding to the solenoid lights up) and
press the [START] key, and the machine repeats operation of ON for 500ms and OFF for 500ms.
This operation is repeated 20 times.
After that, the machine goes into the sub code entry standby mode.
When [INTERRUPT] key is pressed during the process, the machine goes into the sub code input
standby mode. When [CA] key is pressed, the simulation is terminated.
Display lamp
Main cassette lamp
2nd cassette lamp
Manual paper feed lamp
2nd cassette jam lamp
Machine jam lamp & 2nd cassette jam lamp
*
Supported for the installed models only. Skipped for the models without installation.
AR-5316/5320 SIMULATIONS 7-2
Details of operation
Sensor
SPF document set sensor
SPF document transport sensor
SPF unit (OC cover) open/close sensor
SPF paper exit sensor
SPF paper feed cover open/close sensor
SPF paper length sensor 1
SPF paper length sensor 2
SPF paper feed width sensor (small)
SPF paper feed width sensor (middle)
SPF paper feed width sensor (large)
Solenoid
Main cassette paper feed solenoid
* 2nd cassette paper feed solenoid
Manual paper feed solenoid
* 2nd cassette paper transport solenoid
* 3rd cassette transport solenoid