ITEMS
Thermostat
Defrost thermostat
Thermo. fuse
F-fan motor
R-fan motor
(R-fan fuse)
Defrost heater
Door switch
Damper thermostat
Defrost timer
Lamp socket (F/R)
F-lamp
R-lamp
R-fan thermo. R-fan thermo.
ass'y
R-fan thermo.heater
Compressor
Starting relay
Overload relay(Protector) 2.0C36A3
Running capacitor
Ionizer-K(Plasmacluster unit)
LIST OF ELECTRICAL PARTS
TYPE NAME
MM1-8123
125V 6A
250V 3A
S101
250V 8A
SF70E
250V 10A
3R00044B
220-240V 50/60Hz
3R00122A
220-240V 50/60Hz
123
250V 2A
MM6-4198
220-240V 353Ω
DSD-5
250V 0.25A
MM1-6176
—
ND1004M2
220-240V
50/60Hz
—
250V 1A
—
240V 10W
—
240V 15W
S101
250V 8A
RSS2
350V, 2W, 10kΩ
FL2088
220-240V/50Hz
PGT0SAT
—
—
—
4µF,450V
FTRN-A014CBKZ
DC 12V
RATING
(At normal notch)
ON/OFF : -19/-24˚C
Open/Close : 10/1˚C
Working temp. : 70˚C
Working with ø100 fan
Working with ø80 fan
Cut OFF 130˚C
150W at 230V
4 terminals push-button type
Open/Close : 2/-3˚C
Integration type
Cycle time : 10.8/9.0 hours(50/60Hz)
Delay time : 4.3/3.6 min.(50/60Hz)
E-12(Hard plastic body type)
E-12
E-12
Open/ Close : 7/15˚C
1.1W at 230V
Cooling capacity : 245W(50Hz)
Main coil : 9.11Ω
Aux. coil : 16.6Ω
(at 25˚C)
33 Ω ( at 25˚C )
Open/ Close : 130/60˚C
—
3.5kV p-p
7
SJ-P58M/58M
SJ-P63M/63M
SJ-P68M/68M
SPECIFICATIONS
Common
Aux. coil
Main coil