Digital Equipment VAX 4000 100 Kurulum Bilgileri - Sayfa 15

Masaüstü Digital Equipment VAX 4000 100 için çevrimiçi göz atın veya pdf Kurulum Bilgileri indirin. Digital Equipment VAX 4000 100 18 sayfaları.

Digital Equipment VAX 4000 100 Kurulum Bilgileri
If SIMM_OD is not present or not plugged in correctly, the system responds
with a display similar to the following example:
Example 1–2 Unsuccessful Power-Up Test Screen
KA52-A V1.1, VMB 2.14
Performing normal system tests.
72..71..70..69..68..67..66..65..64..63..62..
? Test_Subtest_DC_88 Loop_Subtest=05 Err_Type=FF
Vec=0000 Prev_Errs=0000
P5=00000000 P6=7F337F7F
r0=00000008 r1=21018000
r6=00000002 r7=00000000
dser=0000 cesr=00000000 icsr=01 pcsts=F800 pcctl=FC00 cctl=00000006
bcetsts=03E0 bcedsts=0400 cefsts=00007E80 nests=00 mmcdsr=01FFFE40
mesr=00000000
Error: SIMM Set 0 (0A,0B,0C,0D), SSR = E04E
SIMM_0A = 16MB
Total of 0MB, 0 good pages, 0 bad pages, 0 reserved pages
Normal operation not possible.
>>>
Error Message
Error Summary showing SIMM "0D" is missing
¡
Status Message
¢
If a failure occurs, refer to VAX 4000 Model 100 Troubleshooting and
Diagnostics Information manual.
1–10 Installation Procedure
P1=E04EE04E
P2=00000000
P7=00000000
P8=00000000
r2=E04EE04E
r3=80000000
r8=00000000
r9=20140758 r10=FFFFFFFE r11=FFFFFFFF
SIMM_0B = 16MB
SIMM_0C = 16MB
¢
Note
DE_NO_Memory_present.lis
P3=00000000 P4=00001006
P9=FFFF0000 P10=2006270C
r4=01000000 r5=04000000
¡
SIMM_0D = 00MB ??