Digital Equipment Prioris XL 5200DP Kurulum Kılavuzu - Sayfa 10
Sunucu Digital Equipment Prioris XL 5200DP için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Digital Equipment Prioris XL 5200DP 17 sayfaları. Cpu powergrade kit
Prioris XL and XLDP Server Powergrade Kit
Reset Jumpers on the Main Logic Board
1. As described previously, power down the server.
2. Make sure that the following jumpers, shown in Figure 1, are set to disabled
to prevent any unauthorized update to your BIOS:
J41
BIOS upgrade
J50
Boot block update
Powergrade Installation
Remove the CPU Module
1. Place the antistatic wrist strap on your wrist and connect the grounding
clip to a non-painted metal surface of the computer's chassis.
2. Using a Phillips screwdriver, unscrew and remove the CPU module
retaining bracket (Figure 2).
3. Grasping both ends of the CPU module, carefully remove it from the main
logic board and place it on an antistatic surface.
6
Disabled (Off)
Move the jumper back to the default position
shown in Figure 1 (pin 1 to pin 2).