Siemens SIMATIC NET RUGGEDCOM RS1600 Kurulum Kılavuzu - Sayfa 31

Endüstriyel Ekipmanlar Siemens SIMATIC NET RUGGEDCOM RS1600 için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Siemens SIMATIC NET RUGGEDCOM RS1600 42 sayfaları. Rugged ethernet switches
Ayrıca Siemens SIMATIC NET RUGGEDCOM RS1600 için: Kurulum Kılavuzu (42 sayfalar)

Siemens SIMATIC NET RUGGEDCOM RS1600 Kurulum Kılavuzu
Technical Specifications
5.4 Fiber Optic Ethernet Port Specifications
b
Shielded or unshielded.
c
Auto-crossover and auto-polarity.
d
Typical distance. Dependent on the number of connectors and splices.
e
RMS 1 minute.
5.4

Fiber Optic Ethernet Port Specifications

The following details the specifications for fiber optic Ethernet ports that can be
ordered with the RUGGEDCOM RS1600.
10Base-FL/100Base-SX Ethernet Optic
Connector
Mode
Type
MM
ST
a
Typical.
Fast Ethernet (100 Mbps) Optic
Connector
Mode
Type
MM
MTRJ
SM
LC
a
Typical.
5.5

Operating Environment

Ambient Operating Temperature
Ambient Relative Humidity
Ambient Storage Temperature
5.6

Mechanical Specifications

Ingress Protection
22
All manuals and user guides at all-guides.com
Tx λ
Cable
a
(nm)
Type (µm) Minimum Maximum
820
50/125
-16.5
Tx λ
Cable
a
(nm)
Type (µm) Minimum Maximum
1310
50/125
-16
1310
9/125
-15
Parameter
Weight
Enclosure
Tx (dBm)
Rx
Sensitivity
(dBm)
-10.6
-34.4
Tx (dBm)
Rx
Sensitivity
(dBm)
-11
-33.5
-8
-31
Range
-40 to 85 °C
Measured from a 30 cm (12 in) radius
(-40 to 185 °F)
surrounding the center of the enclosure.
5% to 95%
Non-condensing
-40 to 85 °C
 
(-40 to 185 °F)
10 lb (4.5 Kg)
IP30
18 AWG Galvanized Steel
Rx
Distance
Saturation
Budget
a
(km)
(dBm)
-11.2
2
Rx
Distance
Saturation
Budget
a
(km)
(dBm)
-11
2
-5
15
Comments
RUGGEDCOM RS1600
Installation Manual, 01/2021, C79000-G8976-1013-03
Power
(dB)
21
Power
(dB)
17
16.5