Siemens Simatic S7-1500 Manuel - Sayfa 22

Endüstriyel Ekipmanlar Siemens Simatic S7-1500 için çevrimiçi göz atın veya pdf Manuel indirin. Siemens Simatic S7-1500 40 sayfaları. Digital output module dq 16x230vac/2a st relais (6es7522-5hh00-0ab0)
Ayrıca Siemens Simatic S7-1500 için: Manuel (40 sayfalar), Manuel (37 sayfalar), Manuel (47 sayfalar), Manuel (24 sayfalar), Manuel (34 sayfalar), Kullanıcı Kılavuzu (45 sayfalar), Manuel (27 sayfalar), Yapılandırma Kılavuzu (20 sayfalar), Manuel (47 sayfalar), Manuel (43 sayfalar), Manuel (48 sayfalar), Manuel (26 sayfalar), Manuel (28 sayfalar), Manuel (50 sayfalar), Manuel (34 sayfalar), Kullanıcı Kılavuzu (44 sayfalar), Manuel (50 sayfalar), Manuel (30 sayfalar), Manuel (41 sayfalar), Manuel (50 sayfalar), Güvenlik Programlama Manualline (48 sayfalar), İletişim Talimat Kılavuzu (36 sayfalar), Manuel (40 sayfalar), Manuel (25 sayfalar), Manuel (42 sayfalar), Uygulama Açıklaması (50 sayfalar), Manuel (28 sayfalar), Manuel (33 sayfalar), Manuel (49 sayfalar), Manuel (36 sayfalar), Manuel (41 sayfalar), Manuel (46 sayfalar), Manuel (38 sayfalar), Manuel (35 sayfalar), Manuel (39 sayfalar), Manuel (28 sayfalar), Manuel (35 sayfalar), Ekipman Kılavuzu (35 sayfalar), Manuel (50 sayfalar), Ekipman Kılavuzu (32 sayfalar), Ekipman Kılavuzu (38 sayfalar), Manuel (29 sayfalar), Ekipman Kılavuzu (38 sayfalar), Manuel (34 sayfalar), Manuel (36 sayfalar), Ekipman Kılavuzu (50 sayfalar), Manuel (45 sayfalar)

Siemens Simatic S7-1500 Manuel
Wiring
PROFINET interface (X1) with 2-port switch (X1 P1 and X1 P2)
The following table shows the terminal assignment for the PROFINET interface with 2-port
switch. The assignment corresponds to the Ethernet standard for a RJ45 plug.
Table 3- 2
Reference
You can find additional information on the topics of "Connecting the CPU" and
"Accessories (RJ45 plug)" in the system manual S7-1500 Automation System
(http://support.automation.siemens.com/WW/view/en/59191792).
Assignment of MAC addresses
The CPU 1511-1 PN has a PROFINET interface with two ports. The PROFINET interface
itself has a MAC address, and each of the two PROFINET ports has its own MAC address.
There are therefore three MAC addresses in total for the CPU 1511-1 PN.
The MAC addresses of the PROFINET ports are needed for the LLDP protocol,
for example for the proximity detection function.
The number range of the MAC addresses is sequential. The first and last MAC address
is lasered on the right of each CPU 1511-1 PN.
The table below sets out the MAC address assignment.
Table 3- 3
MAC address 1
MAC address 2
MAC address 3
22
Terminal assignment of PROFINET interface with 2-port switch
View
Assignment of MAC addresses
Assignment
PROFINET interface X1
(visible in STEP 7 for accessible
devices)
X1 P1 port (needed for LLDP, for
example)
X1 P2 port (needed for LLDP, for
example)
Signal name
1
TD
Transmit data +
2
TD_N
Transmit data -
3
RD
Receive data +
4
GND
Ground
5
GND
Ground
6
RD_N
Receive data -
7
GND
Ground
8
GND
Ground
Labeling
Pin assignment
Front, lasered
Right-hand side, lasered
(start of number range)
Front and right-hand side,
not lasered
Front, not lasered
Right-hand side, lasered
(end of number range)
CPU 1511-1 PN (6ES7511-1AK00-0AB0)
Manual, 01/2013, A5E31264526-AA