Ayrıca Siemens SINAMICS S120 için: Kullanım Kılavuzu (20 sayfalar), Başlarken (32 sayfalar), Manuel (41 sayfalar), Kısa Açıklama (22 sayfalar), Deniz Tahrik Uygulamaları İçin Kabinlere Montaj Talimatı (28 sayfalar), Uygulama Kılavuzu (34 sayfalar), Uygulama Kılavuzu (46 sayfalar), Kullanım Talimatları Kılavuzu (22 sayfalar), Başlarken (32 sayfalar), Kullanım Talimatları Kılavuzu (21 sayfalar), Mühendislik El Kitabı (30 sayfalar), Devreye Alma Kılavuzu (20 sayfalar)

Siemens SINAMICS S120 Manuel
SINAMICS S120 Fail-Safe Drives
Task description
The extended safety functions integrated in the SINAMICS S120 drives are
to be controlled from a TM54F via hardware signals. The drives belong to
different drive groups. The safety-relevant logical pre-processing of the
input signals is handled in an F-CPU.
This application should comply with SIL 2 acc. to EN 62061:2005, ISO
13849-1:2006 PL d or EN 954-1:1996 Category 3.
Solution
Hardware overview
The control of the safety functions SS1 and SLS via the TM54F terminal
expansion module connected to a SINAMICS S120 drive group is shown in
this function example. The SLS initiates a Stop C (SS2 → SOS) as re-
sponse to the fault at the particular drive.
The drive group in the booksize format comprises an infeed and a Double
Motor Module. The motor is controlled using a CU320 Control Unit. The ex-
panded setpoint channel is used to enter the speed setpoint. The two ser-
vomotors – that are independent of one another – are controlled by the
Double Motor Module. A Smart Line Module is used as infeed.
The safety-relevant signals are detected using the fail-safe inputs of an F-
CPU and are then evaluated in the F-CPU. The pre-processed signals are
transferred to the TM54F terminal expansion module via the fail-safe
outputs of the F-CPU. This means that the safety functions integrated in the
drive are controlled in the SINAMICS S120.
I DT Safety Integrated
Page 6/43
Entry ID: 28424136
MC-FE-I-005-V11-EN