POWER/PHASE ASSEMBLY REMOVAL AND RE-FITTING, INCLUDING PHASE DRIVER PCB REPLACEMENT
Important Note! Dangerous voltages may be present
inside the Power/Phase assembly. Ensure that the mains
supply is isolated at the Master Switch before
commencing the fitting process.
1.
Isolate the Mains to the ST750 at the master switch.
2.
Disconnect the 64-way Phase Control ribbon cable and
other cables from the CPU.
3.
Unclip the earth lead from the hinged front plate.
4.
Remove the front plate holding the CPU (and I/O or OTU)
and store carefully.
5.
Disconnect the earth wires from the fixing point in the
assembly.
6.
Disconnect PL6, PL7, and SK2.
Warning Care must be exercised when removing or
inserting the green connectors and their cables from the
PCB, as strong extraction and insertion forces are
required. Be careful not to over flex the board, which
could cause tracks to fracture and the board to fail.
7.
Disconnect PL1 and SK1.
8.
Using a medium crosshead screwdriver, loosen (do
not remove) the four screws holding the
Power/Phase assembly to the equipment mounting
plate. Lift the assembly off the mounting plate.
9.
Replace the Phase Drive PCB, as detailed below,
checking that the end part numbers are the same,
i.e. /002 for 2-phase, and /004 for 4-phase.
10. Undo the EMC Filter fixings (M5 stainless screw,
shakeproof washer and nut), so the EMC Filter is
free to move.
11. Remove the Mains Live/Neutral connections to and
from the EMC Filter and Switch.
12. Remove the M3 Hex Spacers that retain the Phase
Driver PCB.
13. Lift out the Phase Driver PCB, noting that it has to
disengage PL1 and SK1.
14. Cut the tie wraps holding the PSU cables, and
unplug the cables from PL2.
15. Remove the PSU from the nylon PCB supports.
16. Fit the new nylon PCB supports to the new Phase
Driver PCB.
17. Fit the PSU onto the new Phase Driver PCB.
18. Plug the PSU cables into PL2, and tie wrap the cables to
the Heatsink/Cover.
19. Fit the Phase Driver PCB into the Power/Phase
assembly.
Notes:
1.
When upgrading to LED Signals, it is recommended that individual neutral returns are used for each green
signal if spare cores are available. Refer to Traffic Signal Junction Cabling Design Certification document
667/DS/20664/000 for more information.
2.
It is recommended that the WID handset command is used to assist Installation and Commissioning.
3.
Traffic Solutions, Siemens Mobility want to assist in the Retrofit process, and have therefore introduced the
option of a basic 'Biscuit Tin', 667/1/27870/799, so that Depots can purchase one or two basic 'Biscuit Tin'
units, and use them to prepare 'Biscuit Tins' with new Phase Driver PCBs for subsequent site installation. The
basic 'Biscuit Tin' includes the Toggle Switch and EMC Filter with associated wiring, and fixings required for the
new Phase Driver PCB.
SUPPLY DETAILS
Siemens Plc
Mobility Division – Traffic Solutions
Sopers Lane, Poole, Dorset, UK
BH17 7ER
667/CI/32755/000 issue 5 (20.01.2015)
20. Fit the M3 Hex Spacers to retain the Phase Driver PCB.
21. Re-fit the Mains Live/Neutral connections to and from the
EMC Filter and Switch, being very careful to fit them
correctly with respect to polarity and Filter input/output,
as shown below.
Fast-on
Tag
TAG1
TAG2
TAG3
TAG4
22. Secure the EMC Filter using the fixings (M5 stainless
screw, shakeproof washer and nut).
23. Ensure that all Phase Driver links and fuses are set
correctly (i.e. in the same position as the original unit),
noting that Wait links and fuses are not present on the
new Phase Driver PCB.
24. Reconnect PL1, PL6, PL7, SK1, SK2 and the earth wires.
25. Replace the hinged front plate holding the CPU PCB and,
if fitted, the I/O or OTU PCB.
Tie
wraps
EMC
Filter
fixings
26. Replace all the cables to the CPU. Clip the earth lead to
the front plate
27. Restore power to the ST750.
Figure 1 – ST750 LED Phase Driver PCB in 'Biscuit Tin'
Tel: +44 (0) 1202 782255 (Support Desk)
Website:
http://www.siemens.co.uk/traffic
Wire Connection
Mains Live from EMC Filter Output (Load)
Mains Neutral from EMC Filter Output (Load)
Mains Live to Switch
Mains Neutral to EMC Filter Input (Line)
Mains Live/Neutral from EMC Filter
Mains Live/Neutral to Switch/EMC Filter
M3 Hex
Spacers
Nylon PCB
Supports
for PSU
M3 Hex
Spacers
Earth
strap to
Door
Page 2 of 2