Siemens CM616GB 1 Series Kullanım Kılavuzu ve Kurulum Talimatları - Sayfa 37
Fırın Siemens CM616GB 1 Series için çevrimiçi göz atın veya pdf Kullanım Kılavuzu ve Kurulum Talimatları indirin. Siemens CM616GB 1 Series 40 sayfaları.
25.3 Installation below a worktop
Observe the installation dimensions and the installation
instructions when installing below a worktop.
25.4 Installation underneath a hob
If the appliance is installed under a hob, the following
minimum dimensions must be adhered to (including
substructure, if applicable).
Hob type
Induction hob
Full-surface induction hob
Gas hob
Electric hob
25.5 Installation in a tall unit
Observe the installation dimensions and the installation
instructions when installing in a tall unit.
a raised in mm
42
52
32
32
¡ To ventilate the appliance, the intermediate floor
must have a ventilation cut-out.
¡ The worktop must be secured to the built-in unit.
¡ Observe any available installation instructions for the
hob.
The minimum worktop thickness
required minimum clearance
a flush in mm
43
53
43
35
¡ To ventilate the appliance, the intermediate floors
must have a ventilation cut-out.
¡ In order to ensure sufficient ventilation of the appli-
ance, there must be a ventilation opening of at least.
200 cm² in the base area. To do this, trim the base
Installation instructions en
a is based on the
.
b in mm
5
5
5
2
37