Technical specifications
Weight:
max. 60 kg
Voltage:
220–240 V, 50 Hz or 60 Hz
Connected load:
1.9–2.3 kW
Fuse:
10/16 A
Water pressure:
at least 0.05 MPa (0.5 bar), maximum
1 MPa (10 bar). At a higher water
pressure: connect pressure-reducing valve
ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
cold water; hot water max. temperature
60 °C.
Installation
The required installation dimensions can
be found in the installation instructions.
Level the appliance with the aid of the
height-adjustable feet. Ensure that the
appliance is situated securely on the floor.
– A built-under or integrated appliance
which is installed subsequently as a
free-standing appliance must be
secured to prevent it from overturning,
e.g. by screwing it to the wall or by
installing it under a continuous worktop
which is screwed to adjacent
cupboards.
– The appliance can easily be installed in
a fitted kitchen between wooden and
plastic walls. If the plug is not freely
accessible, an allpole disconnector
with a contact opening of at least 3 mm
must be fitted on the installation side to
satisfy the relevant safety instructions.
26
Waste-water connection
– The required work sequence can be
found in the installation instructions. If
required, fit a siphon with an drainage
connection.
– Connect the waste-water hose to the
drainage connection of the siphon with
the enclosed parts.
Ensure that the drainage hose is not
kinked, crushed or twisted and that
there is no cover plate in the drainage
to prevent the waste water from flowing
out!
Fresh water connection
– Connect the fresh-water connection to
the tap according to the installation
instructions with the enclosed parts.
Ensure that the fresh-water connection
is not kinked, crushed or twisted.
– When replacing the appliance, always
use a new water supply hose.
Water pressure:
at least 0.05 MPa (0.5 bar), maximum
1 MPa (10 bar). At a higher water
pressure: connect pressure-reducing valve
ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
cold water; hot water max. temperature
60 °C.