Fault
A different error code is
indicated on the digital
display.
( :
to :
)
Display flashes
Refill indicator for rinse-aid
@ is lit.
Refill indicator for rinse-aid
@ is not lit.
Water is left
in the appliance at the end
of the programme.
Cause
A technical fault has probably
occurred.
Door not closed properly.
No rinse aid.
Refill indicator switched off.
There is still enough rinse aid
available.
Filter system or area under
the filters 1R is blocked.
The programme has not yet
ended.
Fault, what to do?
Remedial action
Switch off appliances with the ON/OFF
switch (. After a short time restart
the appliance.
If the problem recurs, turn off the tap and
pull out the mains plug.
Call customer service and mention the error
code.
Close the door. Ensure that no objects
(utensil, fragrance dispenser) are protruding
over the basket and preventing the door
from closing.
Refill rinse aid.
Activation/deactivation (see chapter Rinse
aid).
Check refill indicator, level.
Clean filters and area underneath (see
Waste water pump).
Wait until programme ends or reset (see
Terminating the programme).
aus
25