13) Ink Pump time out error
Details for 9) CR encoder error
Check - for obstruction blocking carriage – Encoder not dirty or scratched – Encoder is installed in the
carriage correctly. (especially if maintenance such as carriage or encoder replacement have happened)
If this error on one
head and nozzle
check is also bad
Air leak/kink in
plumbing
One of the feelers
on the carriage is
obstructed
Air leak/kink in
plumbing
Ink pump is not
working properly
Head could be clogged - replace
carriage
Check the line - replace if
necessary
Release the carriage and make
sure that the feeler for that
channel is not obstructed (see
picture in Detail for 7)
Check the line - replace if
necessary
Check connections on the ink
supply unit. Replace if necessary