ACTUATECH GD08 Kullanım Kılavuzu - Sayfa 13
Kontrolör ACTUATECH GD08 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. ACTUATECH GD08 14 sayfaları. Scotch–yoke part turn pneumatic actuator
![ACTUATECH GD08 Kullanım Kılavuzu](/uploads/products/server2/55096/55096.jpg)
9. STORAGE
The ACTUATECH actuator has been packaged to provide protection during shipment, however, it can be damaged in transport. Prior
to storage, inspect the actuator for shipping damage. Keep the actuators in their original packing box during storage.
It is recommended to keep the actuators in a clean and dry environment at temperatures between -10°C and +60°C until ready for
use.
The actuator has two air ports, which are closed by labels for prevent liquids or others material to entering in the actuator during
storage.
If the actuators are to be stored for a long period of time before installation, it is recommended to stroke them periodically to prevent
setting of the seals.
WARNING
Keep the actuator in its original box until the installation, and store it indoors, in dry and clean environment, at temperatures
between -10°C and +60°C to protect them from humidity and dust.
10. TROUBLESHOOTING
POTENTIAL EFFECT OF FAILURE
Loss or reduction of the supplied
torque
Leaks from the stem upper or lower
seals
Leakage form cylinder caps
Leakage from the ports after
manoeuvre
Insufficient valve rotation
ACTUATECH S.p.A
Via S. Lorenzo, 70, 25069 Villa Carcina (BS) Italy •
Rif. MAN80938 - 02/22
SCOTCH–YOKE PART TURN PNEUMATIC ACTUATOR
POTENTIAL CAUSE OF FAILURE
Lack of supply
Air supply not enough to produce
required torque
Air leakage from seals
Stem O-ring seal damage
Damages on the body Shaft damaged
Shaft damaged
Seals damaged
Damaged piston seal
Damaged body cylinder
Increase of valve manoeuvre torque
Air supply not enough to produce
required torque
Mechanical stop (if there) not duty
adjusted
Wrong connection between the actuator
and the valve stem
Ph.
+39 030 8908142 •
Fax
+39 030 8908143 • [email protected] •
INSTRUCTION MANUAL
SOLUTION
Verify that the actuator has been con-
nected to the pneumatic line correctly
Verify that the supply pressure value cor-
responds to the functioning requirements
(see actuator data plate)
Verify that the screws are completely
tightened
Contact ACTUATECH for repair
Replace the seals
(see "Maintenance" chapter)
Replace the piston seals
(see "Maintenance" chapter)
Contact ACTUATECH for repair
Verify the valve release torque and the
possibility to replace with a new one
Increase the air supply
Adjust the stops by increasing the stroke
Check the connection elements between
the valve and the actuator
www.actuatech.com
GD08
13
EN -