ACTUATECH GS1440 Kullanım Kılavuzu - Sayfa 16

Kontrolör ACTUATECH GS1440 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. ACTUATECH GS1440 16 sayfaları. Scotch–yoke part turn pneumatic actuator

ACTUATECH GS1440 Kullanım Kılavuzu

11. TROUBLESHOOTING

POTENTIAL EFFECT OF FAILURE
Loss or reduction of the supplied
torque
Leaks from the stem upper or lower
seals
Leakage form cylinder caps
Leakage from the ports after
manoeuvre
Insufficient valve rotation
12. DISPOSAL OF PRODUCTS AT THE END OF THEIR LIFE CYCLE
The ACTUATECH products are designed so that when they are at the end of their life cycle they can be completely disassembled,
separating the different materials for the proper disposal and/or recovery. All materials have been selected in order to ensure minimal
environmental impact, health and safety of personnel during their installation and maintenance, provided that, during use, they are
not contaminated by hazardous substances.
The personnel in charge of the product disposal/recovery, must be qualified and equipped with appropriate personal protective equi-
pment (PPE), according to the product size and the type of service for which the device was intended. The management of waste
generated during the installation, maintenance or due to the product disposal, is governed by the rules in force in the country where
the product is installed, in any case, the following are general guidelines:
- The metal components (aluminium/steel) can be restored as raw material;
- Seals/sealing elements (NBR, FPM, FVMQ...), as contaminated by fluids from other materials and lubrication, must be disposed of.
- The packaging materials that come with the product, should be transferred to the differentiated collection system available in the
country.

13. DECLARATION OF CONFORMITY

The ACTUATECH S.p.A. actuators have been designed, manufactured and tested to meet the requirements of the following Europe-
an standards and are marked, where provided, with the relative CE conformity marking:
- 2006/42/EC Directive "Machinery";
- 2014/34/EU Directive "Equipment and protective systems intended for use in potentially explosive atmospheres" (ATEX).
- Regulation (EC) No 1907/2006 and successive concerning the Registration, Evaluation, Authorization and Restriction
of Chemicals (REACH).
ACTUATECH S.p.A
Via S. Lorenzo, 70, 25069 Villa Carcina (BS) Italy •
Rif. MAN80937 - 03/22
SCOTCH–YOKE PART TURN PNEUMATIC ACTUATOR
POTENTIAL CAUSE OF FAILURE
Lack of supply
Air supply not enough to produce
required torque
Air leakage from seals
Stem O-ring seal damage
Damages on the body
Shaft damaged
Seals damaged
Damaged piston seal
Damaged body cylinder
Increase of valve manoeuvre torque
Air supply not enough to produce
required torque
Mechanical stop (if there) not duty
adjusted
Wrong connection between the actuator
and the valve stem
Ph.
+39 030 8908142 •
Fax
+39 030 8908143 • [email protected]
GD2880 - GD8000 AND GS1440 - GS4000
Verify that the actuator has been con-
nected to the pneumatic line correctly
Verify that the supply pressure value cor-
responds to the functioning requirements
(see actuator data plate)
Verify that the screws are completely
Contact ACTUATECH for repair
Replace the seals
(see "Maintenance" chapter)
Replace the piston seals
(see "Maintenance" chapter)
Contact ACTUATECH for repair
Verify the valve release torque and the
possibility to replace with a new one
Increase the air supply
Adjust the stops by increasing the stroke
Check the connection elements between
the valve and the actuator
INSTRUCTION MANUAL
SOLUTION
tightened
www.actuatech.com
16
EN -