5.2 MULTIPLE HNS050MD WIRING
•
Multiple HNS050MD can be used to start a single Cabac S-Click 2- Wire or Cabac S-Click 3-Wire Timer.
•
Refer to Figure 4 and 5 for the different methods of connecting a timer with multiple HNS050MD.
•
There is effectively no limit to the number of HNS050MD that can be connected to a single circuit provided the
total trigger wire length does not exceed 50m.
Active
Neutral
HNS050MD
Active
Neutral
HNS050MD
6. SUITABLE PLACEMENT FOR HNS050MD
6.1 SUGGESTED HALLYWAY LOCATIONS
6.2 SUGGESTED ROOM LOCATIONS
Customer Care Australia P: 133 122 F: 1300 303 310 E: [email protected] W: cabac.com.au
A: 8 Distribution Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: [email protected] W: cabac.co.nz
HNS050MD MOTION DETECTOR 3-WIRE
WIRING DIAGRAM FOR THE HNS410TM / HNS420TM
CONTROLLED BY MULTIPLE HNS050MD MOTION DETECTORS
Trigger
Trigger
Active
Neutral
Figure 4
WIRING DIAGRAM FOR THE HNS440TM / HNS450TM
CONTROLLED BY MULTIPLE HNS050MD MOTION DETECTORS
Trigger
Trigger
Active
Neutral
23 March 2015
Hallway1-Issue 06A
Figure 5
Load
Loop
Active
HNS050MD
HNS410TM / HNS420TM
Remote
Active
Neutral
HNS050MD
HNS440TM / HNS450TM
Neutral