3Com 3C13641 Başlangıç Kılavuzu - Sayfa 11
Ağ Yönlendiricisi 3Com 3C13641 için çevrimiçi göz atın veya pdf Başlangıç Kılavuzu indirin. 3Com 3C13641 17 sayfaları. 3000 adsl2 plus family
3Com Router 3000 ADSL2+ Family Getting Started Guide
Important Safety Information
WARNING: Installation and removal of Router 3000 units must be carried out by qualified personnel only.
WARNING: The unit must be connected to an earthed power supply to ensure compliance with safety
standards.
WARNING: Power Cord Set:
This must be approved for the country where it is used.
U.S.A. and
Canada
United Kingdom
Only
Europe Only
Denmark
Switzerland
WARNING: France and Peru only:
This unit cannot be powered from IT
230V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point labeled Neutral,
connected directly to earth (ground).
†
Impédance à la terre.
WARNING: The appliance coupler (the connector to the unit and not the wall plug) must have a
configuration for mating with an EN60320/IEC320 appliance inlet.
WARNING: The socket outlet must be near to the unit and easily accessible.
WARNING: This unit operates under SELV (Safety Extra Low Voltage) according to IEC 60950. The
conditions are only maintained if the equipment to which it is connected also operates under SELV
conditions.
WARNING: To avoid electric shock or damage to the equipment, do not connect Safety-Extra-Low-Voltage
(SELV) circuits to telephone-network-voltage (TNV) circuits.
WARNING: RJ-45 Ports. These are shielded RJ-45 data sockets. They cannot be used as standard
traditional telephone sockets, or to connect the unit to a traditional PBX or public telephone network. Only
connect RJ-45 data connectors, network telephony systems, or network telephones to these sockets.
Either shielded or unshielded data cables with shielded or unshielded jacks can be connected to these data
sockets.
WARNING: If installing products of different depths together (one on top of the other), the shallower
products should be installed above the deeper products.
The cord set must be UL-approved and CSA certified.
The minimum specification for the flexible cord is:
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at least 10A.
The attachment plug must be an earth-grounding type with a NEMA 5-15P (15A,
125V) or NEMA 6-15P (15A, 250V) configuration.
The supply plug must comply with BS1363 (3-pin 13 amp) and be fitted with a 5A
fuse that complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and be of type
H03VVF3GO.75 (minimum).
The supply plug must comply with CEE 7/7 ("SCHUKO").
The mains cord must be <HAR> or <BASEC> marked and be of type
H03VVF3GO.75 (minimum).
The supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-
5a.
The supply plug must comply with SEV/ASE 1011.
†
supplies. If your supplies are of IT type, this unit must be powered by
9