(SECTION
3 • PLACEMENT
)
Now that setup is complete, you must choose a location to place the wireless
sensor and the main unit. The wireless sensor MUST be placed less than 100
feet away from the main unit.
This wireless thermometer uses radio frequency for communication, which is
susceptible to interference from other electronic devices and large metallic
items or thick walls. Always place both units at least 3 feet away from
appliances
I
TV, microwave, radios, computers, etc.
I
or objects that may
interfere with the wireless communication
I
large metal surfaces, thick stone
walls, etc. ].
--'01'.,.
- -
,; I \'
100 feet maximum
Placement of Main Unit
Place the main unit in a dry area free of dirt and dust. To help ensure
an accurate indoor temperature measurement, be sure to place the
main unit out of direct sunlight, and away from any heat sources or
vents in your home. There are 2 placement options for the main unit.
You may hang the main unit on a wall using the integrated hang hole.
Alternatively, you may place the main unit on a table top or other flat
surface.
Placement of Sensor
The wireless sensor MUST BE PLACED OUTDOORS to observe
outdoor temperatures. The wireless sensor must be placed less than
100 feet from the main unit.
The wireless sensor is water resistant and is designed for general
outdoor use. However, to extend the life of the product, place the
wireless sensor in an area protected from direct weather elements.
To ensure an accurate outdoor temperature measurement, be sure
the wireless sensor is placed out of direct sunlight and away from any
heat sources.
There are 2 placement options for the wireless sensor. You may hang
it on a wall using one of the two integrated hang holes, or use string
[not included] to hang it from a suitable location like a well covered
tree branch.
-
4
-
Troubleshooting
Problem
Possible Solution
Bad
Wireless Sensor
Reception
( no temperature reading)
,
OF
• Make certain that the batteries are installed
correctly into the wireless sensor. The
wireless sensor batteries may need
replacing.
• Relocate the main unit and/or the wireless
sensor. Both units must be within 100 feet
from each other.
• Make sure both units are placed at least 3
feet from other electronic appliances and
devices that may interfere with the wireless
communication [such as TV's, microwaves,
radios, computers etcl.
• Make certain there are no large metallic
Tull
-
-out
1..olllll
no bars
12:35pm
surfaces or very thick stone walls or surfaces
between the wireless sensor and the main
unit.
,noF.
IU
1n
• Metal screens or LOW-E windows may
interfere with the wireless communication.
• In some cases, relocating AND resetting
the main unit and wireless sensors
[removing and re-installing batteries) may be
necessary.
NOTE: It may take up to 20 minutes for the
main unit to re-synchronize with the sensor
when batteries are replaced. Use lithium
batteries in sensor when temperature is
below -4°F.
Main Unit
Display Not Working
Make certain that the batteries are installed
correctly. The batteries may need replacing.
Please DO NOT return
product to the retail store.
For technical assistance and product return information, please call
Customer Care:
877-221-1252
Mon. - Fri. 8:00 A.M. to 4:45 P.M. (CST]
www.chaneyinstrument.com