1-8. Signal Inputs and Outputs

1-9. Switch Settings on Connector Panel

VIDEO CONTROL: 15-pin (male)
External view
1
9
Pin No. Signal
1
SYNC CONT (Input)
2
HUE CONT (Input)
3
SC CONT (Input)
4
VIDEO LEVEL CONT (Input)
5
SETUP CONT (Input)
6
CHROMA LEVEL CONT (Input)
7
REG _12V (Output)
8
GND
9 to 12 NC
13
Y/C DELAY CONT (Input)
14
NC
15
REG +12V (Output)
* : Not use in DNW-75/75P/65/65P.
CONTROL PANEL: 29-pin (female)
External view
10
19
29
Pin No.
Signal
1
GND
2
KEY RX (_) (Input)
3
KEY TX (+) (Output)
4
GND
5 to 7
REG +8V (Output)
8, 9
NC
10, 11
GND
12
KEY RX (+) (Input)
13
KEY TX (_) (Output)
14
GND
15 to 17
REG +8V (Output)
18
NC
19 to 23
GND
24 to 26
REG +8V (Output)
27, 28
NC
29
GND
1-14
8
15
Terminal voltage (V)
_5 to +5
_5 to +5
_5 to +5
_5 to +5
_5 to +5
_5 to +5
_12
——
——
*
_5 to +5
——
+12
1
11
20
Terminal voltage (V)
——
RS422
RS422
——
+8
——
——
RS422
RS422
——
+8
——
——
+8
——
——-
1-9. Switch Settings on Connector Panel
When the unit is installed, be sure to perform the following
setup.
Refer to the operation manual "Section 2 Location and
Function of Parts" for setup.
. 75 Z termination switch of reference video input
. 75 Z termination switch of composite video input
(DNW-75/75P only)
. Analog audio input level/600 Z termination switches
(DNW-75/75P only)
DNW-75/75P
DNW-65/65P