VISCA Device Setting Command
Before starting control of the BRC-Z700, be sure to send
the Address command and the IF_Clear command using
the broadcast function.
For VISCA network administration
•
Address
Sets an address of a peripheral device. Use when
initializing the network, and receiving the following
network change message.
•
Network Change
Sent from the peripheral device to the controller when
a device is removed from or added to the network. The
address must be re-set when this message is received.
Packet
Address
88 30 01 FF
Network Change
X0 38 FF
X = 9 to F: BRC-Z700 address + 8
VISCA interface command
•
IF_Clear
Clears the command buffers in the BRC-Z700.
When cleared, the operation currently being executed
is not guaranteed.
Command Packet
IF_Clear
8X 01 00 01 FF
IF_Clear (broadcast)
88 01 00 01 FF
X = 1 to 7: BRC-Z700 address (For inquiry packet)
X = 9 to F: BRC-Z700 address +8 (For reply packet)
VISCA interface and inquiry
•
CAM_VersionInq
Returns information on the VISCA interface.
Inquiry
Inquiry Packet Reply Packet
CAM_VersionInq 8X 09 00 02 FF Y0 50 GG GG HH HH JJ JJ KK FF GGGG = Vender ID
X = 1 to 7: BRC-Z700 address (For inquiry packet)
X = 9 to F: BRC-Z700 address +8 (For reply packet)
6
Note
Always broadcasted.
Reply Packet
Note
X0 50 FF
88 01 00 01 FF
Description
(0001: Sony)
HHHH = Model ID
0501: BRC-H700
0502: BRU-H700
0505: BRC-Z700
JJJJ = ROM revision
KK = Maximum socket # (02)