16 - MATCH BETWEEN REMOTE CONTROLLER AND INDOOR UNIT
EN
(TRANSMISSION CHANNEL)
The remote control can be addressed to use up to 4 different units installed in the same room.
You can get unified control by using a single remote control for all units or each remote control can be addressed to its
own unit, in order to control separately temperature, timer and all other functions.
PCB SETTING
• Disconnect the unit power supply and wait at least 60 seconds, making sure that all the lamps go off.
• Remove the front panel to access the pcb.
• Set SW1 as shown in the table.
• Close the front panel.
• Reconnect the unit power supply.
REMOTE CONTROLLER SETTING
• Press the button
• Press the arrow
• Press the button
• Press the arrow
• Confirm with the button
• Press
to exit the menu.
CHANNEL
FACTORY STATE
1
2
3
for a few seconds.
until you visualize 08.
again for a few seconds: the number 0 (factory setting) at the bottom starts flashing.
to set 0, 1, 2 or 3.
.
REMOTE CONTROL UNIT
0
SW1: 1=OFF 2=OFF
SW1: 1=ON 2=OFF
SW1: 1=OFF 2=ON
SW1: 1=ON 2=ON
16
UNIT PCB