Sony XCD-SX90 Teknik Kılavuz - Sayfa 16

Dijital Kamera Sony XCD-SX90 için çevrimiçi göz atın veya pdf Teknik Kılavuz indirin. Sony XCD-SX90 38 sayfaları. Digital camera module
Ayrıca Sony XCD-SX90 için: Manuel (4 sayfalar), Teknik Kılavuz (39 sayfalar), Servis Kılavuzu (30 sayfalar), Kullanım Talimatları (2 sayfalar)

Sony XCD-SX90 Teknik Kılavuz

Control

Camera Command Status Register

This camera complies with IIDC 1394-based Digital Camera Specification, Version 1.31 (hereinafter referred to as IIDC
v1.31).
The standards document can be purchased from 1394TA (the 1394 Trade Association). As it is very helpful in
understanding the explanations in this Technical Manual, we recommend that you purchase a copy of IIDC v1.31.
Memory Map
BusID
bbbbbbbb
1394 devices have a 64-bit address space. The upper 10
bits show the bus ID (0-1023), and the next six bits show
the node ID (0-63). The IIDC standards require the next
20 bits to be 1.
The remaining 28 bits can be allocated to the camera as
addresses.
The bus and node IDs may be changed if the topology is
restructured because of bus reset, so only the least
significant 32 address bits are shown in this Guide.
16
NodeID
Must be 1
bbnnnnnn
11111111
11111111
Address used by the camera
11110000
11110000
00000000
Address
F0000000
F0000400
F0F00000
F0F00000
F0F00100
F0F00180
F0F00200
F0F002E0
F0F00400
F0F00500
F0F00600
F0F0071C
F0F00800
F0F00970
F0F10000
F0F11000
F0F12000
F0F13000
F0F30000
F0F40000
F0F50000
F0F60000 – F0F61FFC
F0F62000 – F0F62020
F0F63000 – F0F63024
F0F64000 – F0F64020
00000000
Resister
Base address
ConfigROM area
Base address for camera
commands
CameraInitialize
Video Format Inq
Video Mode Inq
Frame Rate Inq
Format7 CSR Inq
Basic Func Inq
Feature Element Inq
Isochronous Control register
AbsoluteControlCSR Inq for
Shutter
FeatureControl
AbsoluteControlCSR for Shutter
Format7Mode0 CSR
Format7Mode1 CSR
Format7Mode2 CSR
Format7Mode3 CSR
AccessControlRegister
MemoryShotControl
UserFreeMemory
LookUpTable
Filter
AWB parameters
AE parameters