Sony XCI-V100C Teknik Kılavuz - Sayfa 12

Dijital Kamera Sony XCI-V100C için çevrimiçi göz atın veya pdf Teknik Kılavuz indirin. Sony XCI-V100C 23 sayfaları. Intelligent

Strobe Delay

A strobe control signal is assigned to the tenth pin on the
12-pin connector, allowing direct control of light-
emission from a strobe connected to the camera. In
addition, you can configure a delay in the timing for
light-emission in relation to the timing for exposure.
Available strobe delay settings
0 to 4 ms (1 us steps)
Exposure timing
Strobe signal output
One Trigger Two Frame Capture
Mode
This camera can capture two sequential frames of an
image in response to a single trigger input. The shutter
speed can be configured for each frame. Since internal
triggers are continuously generated, this function is also
available during monitoring (free run) mode.
The following settings can be configured here.
• Configure individual shutter speeds for the first and
second frames.
• Automatically configure the shutter speed for first
frame to a value that is incremental to the shutter speed
manually configured for the second frame.

Trigger Counter

A built-in trigger counter allows the camera to count the
number of input pulses for external triggers.
Counter values can be confirmed and reset.

Shared Trigger Function

This camera is equipped with shared trigger function
that allows multiple cameras to be operated sequentially
in response to a single trigger input.
For each fixed number of triggers that are input (trigger
cycle), each camera performs one shooting operation.
12
Delay
1
2
3
Trigger
Trigger generating device
1
2
Camera
Exposure
Exposure
during
during
trigger 1
trigger 2
Input wave diagram when the trigger pulse is input to
four cameras
4
1
2
3
4
3
4
Exposure
Exposure
during
during
trigger 3
trigger 4