Sony XCL-CG510C Teknik Kılavuz - Sayfa 31
Dijital Kamera Sony XCL-CG510C için çevrimiçi göz atın veya pdf Teknik Kılavuz indirin. Sony XCL-CG510C 48 sayfaları. Digital video camera module
Sensor Readout (Sensor Output)
This signal indicates that exposure has completed and the image sensor has entered the video output sequence (enabled
only when operating the trigger mode). Output is available from the GPO2 or 3 terminals. The sensor readout signal is
asserted before optical black (OB) and the effective pixel area is output. Image might not be output properly, if trigger
signal is input while this signal is asserted.
Trigger signal
Exposure signal
Sensor readout signal
(Sensor output)
Pulse Train Generator
Pulse waveforms can be output from the GPO connector. Available range is 0.5Hz to 100kHz.
Command
PULSE-DUTY
PULSE-CYCLE
Status LED
LED on the rear panel lights up according to the output specification set for GPO1 connector. Various settings are
possible such as assigning the trigger signal and pulse train generator. The setting is saved immediately and reflected at
the next startup.
Command
Parameter
LED-MODE
0
1
2
3
4
5
Trigger latency
Parameter
1 to 2000000 [µs]
10 to 2000000 [µs]
Setting
Off
On
GPO1 setting
GPO2 setting
GPO3 setting
GPO4 setting
31