Sony XCU-CG160 Teknik Kılavuz - Sayfa 8
Dijital Kamera Sony XCU-CG160 için çevrimiçi göz atın veya pdf Teknik Kılavuz indirin. Sony XCU-CG160 45 sayfaları. Digital video camera module
Functions
Default value for each item is underlined.
Trigger Signal Input
Trigger signals can be input via pins 2, 3, and 4 of the DC power supply input connector, or by software command.
Switchover of the trigger signal can be changed using TriggerSource. For details, see "Trigger Control" (page 17).
Trigger signal polarity
Positive polarity refers to a trigger signal activated by a Low to High rising edge, or High-level interval. Negative
polarity refers to a trigger signal activated by a High to Low falling edge, or Low-level interval. The default value of the
camera is negative polarity.
Feature
Parameter
TriggerActivation
FallingEdge (0)
RisingEdge (1)
DC power supply input connector specifications
2.0 µs or less
10 µs to 2 s
2.0 µs or less
10 µs to 2 s
Notes
• When inputting a trigger signal to the camera using the DC-700/700CE, use 5 V DC or lower as the logical high level.
• Make sure to supply power to the unit and confirm that the unit is operating before inputting a trigger signal. If you
input a trigger signal to the unit without the power supplied, this may cause a malfunction of the camera.
Setting
Negative
Positive
2.0 µs or less
1 frame cycle or longer
Trigger input polarity = Negative
2.0 µs or less
1 frame cycle or longer
Trigger input polarity = Positive
5 V to 24 V (pin 2 of the DC power supply
input connector)
3.5 V to 5.5 V (pin 3 of the DC power
supply input connector)
0 V to 0.4 V
5 V to 24 V (pin 2 of the DC power supply
input connector)
3.5 V to 5.5 V (pin 3 of the DC power
supply input connector)
0 V to 0.4 V
8