ACU-RITE SENC 150 Kurulum Kılavuzu - Sayfa 8
Medya Dönüştürücü ACU-RITE SENC 150 için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. ACU-RITE SENC 150 8 sayfaları. Chevalier fsg-2a 1224 surface grinder cross feed “x” axis
Ayrıca ACU-RITE SENC 150 için: Referans Kılavuzu (20 sayfalar), Kurulum Kılavuzu (4 sayfalar), Kurulum Kılavuzu (6 sayfalar), Talimatlar Kılavuzu (12 sayfalar)
SENC 150
Bracket assembly
mounting plate
.03" - .18" Gap
•
Adjust the mounting plate clearance so that a gap
of .03" - .18" exist.
•
Align the reading head mounting holes with the
mounting plate tapped holes.
•
Secure the bracket assembly in place.
*Leveling set screw (3)
* 8-32 x 5/8" SHCS (2)
•
Insert the two *8-32 x 5/8" SHCS. Insure the
bracket assembly is adjusted to provide proper
screw head clearance. Do Not Tighten Screws at
this time.
•
Set each leveling set screw by placing a .001" - .003"
feeler gage between the set screw and the bracket.
•
Adjust each set screw until a slight drag is felt on
the feeler gage.
•
Evenly tighten the two 8-32 SHCS.
P.N. 385072-222 Ed B 11/05
Encoder button up ...
•
•
•
•
•
•
•
Acu-Rite Companies Inc.
One Precision Way • Jamestown, NY 14701
4
Encoder Installation Manual For: Vertical Knee Mill
Cross Feed Y Axis on Right Hand Side
Slide brackets back
away from the
reading head and
cable
Use allen wrench from set screw adjustment to
slide alignment brackets away from the reading
head.
Remove alignment brackets and save for possible
future use.
Move the axis through its full travel. Confirm that
the assembly does not interfere with the machine
movement.
With the longitudinal axis installation complete,
route the cables providing sufficient slack loops for
machine movement to the readout.
Secure cables by fastening with clips or ties.
Attach the linear encoder connectors to the readout.
Complete the installation by following the steps in
"Checking Your Installation" section in the encoder
"Reference Manual".
Twist brackets
45° to remove
Installation Manual 385072-45