S S F F X X 0 0 6 6 4 4 D D T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g
If the sound does not start in the decoder
1. Make sure you have selected the locomotive on a throttle. The sound will
not run unless the locomotive is addressed in the system.
2. Check your installation to make sure the decoders are installed properly.
If the sound output sounds distorted
1. Check the speaker cone for magnetic debris that may have collected there.
Debris on the speaker will cause a loss of sound quality and must be removed.
2. Be sure that the CV58 volume is not set at a level that is too high for the
speaker. For impedances below 32ohms (e.g. 8 to 30 ohms) set the volume set-
ting lower to ensure the 1 watt output rating is not exceeded.
If the sound in your decoder shuts down after you stop it and you are not
using a Digitrax system for control. On some DCC systems decoders are not
addressed by DCC packets after the locomotive is set to 0 speed. In this case
after the CV11 timeout elapses (6 second default), sound will "shutdown.". To
defeat this feature, set CV11=00 to remove the timeout and shutdown. To make
sounds, the decoder must have a command addressed to it at least once.
If you have trouble reading back CV's on the programming track, this may
be due to insufficient current draw on the SFX064D function leads. Of course
you can always just re-program the CV value into a CV to get the desired
results, even though reading CV's does not work. OPs mode is recommended
for programming all CVs except CV01, CV17 & CV18 (2 digit and 4 digit
addresses). If a second DCC decoder is present that is not Sound FX compati-
ble then correct readback of CV data is not possible,since the NMRA CV read-
back was not designed for multiple decoder readback.
The SFX064D plays a Diesel scheme, but I want the default steam scheme.
If the factory scheme has not been erased, program CV60 to a value of 0 to res-
elect the Steam scheme. Alternatively set CV60 to 01 to change to the SD38-2
sound scheme.
I have loaded a new scheme but the CV's and Functions are not what I
expected. Load the sound project you programmed and then select the
"view>project description" menu and then read the text file on the screen that
defines how that project in particular uses CV's and Functions for sound gener-
ation and configuration.