Checking the VIP6-80 Installation
This section describes the procedures you can use to verify your VIP6-80 installation, and includes
information on the following topics:
•
•
•
•
Verifying the Installation
This section describes how to verify the VIP6-80 installation by observing the port adapter LED states
and the information displayed on your console terminal.
The VIP6-80 has no LEDs that are visible or usable when the VIP6-80 is installed. The port adapters you
Note
install on the VIP6-80 have status and interface LEDs.
When the system has reinitialized all interfaces, the enabled LED on the VIP6-80 port adapters should
go on, depending on your connections and configuration. The console screen also displays a message as
the system discovers each interface during its reinitialization.
The following sample display shows the events logged by the system as a VIP6-80 with a Gigabit
Ethernet port adapter was removed from interface processor slot 2; the system then reinitialized the
remaining interface processors and marked as down the Gigabit Ethernet interface on the VIP6-80 that
was removed from slot 2. When you reinsert the VIP6-80, the system automatically brings up the
interfaces that were up when the VIP6-80 was removed. (A Gigabit Ethernet interface is used in the
following examples.)
Removal
Router#
%OIR-6-REMCARD: Card removed from slot 2, interface disabled
%LINK-5-CHANGED: Interface GigabitEthernet2/0/0, changed state to administratively down
Insertion
Router#
%OIR-6-INSCARD: Card inserted in slot 2, interface administratively shut down
%LINK-5-CHANGED: Interface GigabitEthernet2/0/0, changed state to up
When a new VIP6-80 is inserted or when a VIP6-80 is moved to a new slot, the system recognizes the
Note
new interfaces but leaves them in the shutdown state until you configure them and change their state to
up.
The following sample display shows the events logged by the system as you insert a new VIP6-80 in
interface processor slot 3. (A Gigabit Ethernet interface is used in the following example.)
Router#
%OIR-6-INSCARD: Card inserted in slot 3, interface administratively shut down
Versatile Interface Processor (VIP6-80) Installation and Configuration Guide
26
Verifying the Installation, page 26
Using show Commands to Verify the VIP6-80 Status, page 28
Using show Commands to Display Interface Information, page 29
Using the ping Command to Verify Network Connectivity, page 31