Installing the High Speed Fan Tray
To install the high speed fan tray (WS-C6509-NEB-FAN2), follow these steps:
Hold the fan tray with the fans facing down and the FAN FAIL LED on the right. (See
Step 1
Figure 4
Captive installation
Place the fan tray into the front chassis cavity so that it rests on the chassis, and then lift the fan tray up
Step 2
slightly, aligning the top and bottom chassis guides.
Push the fan tray into the chassis until the power connector seats in the backplane and the captive
Step 3
installation screws make contact with the chassis.
Use a flat-blade or number 2 Phillips-head screwdriver to tighten the captive installation screws.
Step 4
Proceed to the
Step 5
78-16162-02