Network Cabling and Interface Considerations
For additional information on the power requirements, see the Cisco VG410 Voice Gateway Datasheet.
Warning
Network Cabling and Interface Considerations
Network Cabling Considerations
The following are the cable types that are used in the Cisco VG410 Voice Gateway:
• GE cables (RJ-45 to RJ-45 straight-through cables)
• Analog voice cables (RJ-21)
Interface Considerations
When you run cables for any significant distance in an electromagnetic field, interference can occur between
the electromagnetic field and the signals on the cables. This has two implications for the installation of terminal
plant cabling:
• Unshielded plant cabling can emit radio interference.
• Strong electromagnetic interference (EMI), especially as caused by lightning or radio transmitters, can
If you use twisted-pair cables with a good distribution of grounding conductors in your plant cabling, emitted
radio interference is unlikely.
If you have cables exceeding recommended distances, or if you have cables that pass between buildings, give
special consideration to the effect of lightning strikes or ground loops. If your site has these characteristics,
consult experts in lightning suppression and shielding. The electromagnetic pulse caused by lightning or other
high-energy phenomena can easily couple enough energy into unshielded conductors to destroy electronic
devices.
Most data centres cannot resolve such infrequent but potentially catastrophic problems without pulse meters
and other special equipment. Take precautions to avoid these problems by providing a properly grounded and
shielded environment and by installing electrical surge suppression.
For advice on the prevention of electromagnetic interference, consult experts in radio-frequency interference
(RFI).
Tools and Equipment Required for Installation
You need the following tools and equipment to install and upgrade the voice gateway and its components:
• Standard flat-blade screwdriver as required for attaching the brackets for rack mounting.
Cisco VG410 Voice Gateway Hardware Intallation Guide
16
Statement 1005
Circuit Breaker
This product relies on the building's installation for short-circuit (overcurrent) protection. To reduce risk of
electric shock or fire, ensure that the protective device is rated not greater than 20A.
destroy the EIA/TIA-232 drivers and receivers in the Cisco VG410 Voice Gateway.
Planning the Installation