Digiway P750L Kullanım Kılavuzu - Sayfa 8

Garaj Kapısı Açıcı Digiway P750L için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Digiway P750L 13 sayfaları. Sliding gate motor

Factory setting
Timer
Open Cycle Time
Close Cycle Time
Ped Cycle Time
Sync Delay Time
Auto Close Time
PE Auto close Time
Warning time
Lock Pulse Time
Light Time
Motor Stop Time
Two-T1 Time(spare)
Two-T2 Time(spare)
To restore factory setting, turn power off and set SET1 on, push and hold CLS
button, then power on. While hold CLS button, set SET1 off and then release the
CLS button. Now controller restored factory setting from memory.
3. Light output
With the additional module, which plugs into the control board, the control board will control
light, which will illuminate the driveway etc. The light will automatically turn off after preset time
(customer programmable). If DIP4 is set to ON, the M2 output will change to light output.
4. Audio warn output
On Board buzzer can give warn for diagnose. Additional buzzer or relay module, which plugs into the
control board, the control board give out audio warning signals before gate moves
If PB beam is blocked or Stop input is not shorted, four short bee will be heard
5. Inverter settings
Different inverter and setting are different. P750V5.0 can control nearly all model inverter. 12V or 24V
accessories power supply. PNP or NPN output. Here is some samples.
a) TECO FM 50 inverter. 12V, PNP output, now it is no longer
available.
Function
Acceleration time
Deceleration time
Freq. Upper limit
Freq. Lower limit
SP1 Frequency
Start/Stop/Control
Multifunction Input
SP2 Frequency
SP3 Frequency
P750LV2.1 industrial gate motor manual
F/Setting
Step
60sec.
0.1sec
60sec.
0.1sec.
10sec.
0.1sec.
2sec.
0.1sec.
30sec.
0.1sec.
2sec.
0.1sec.
3sec
0.1sec
1sec.
0.1sec
60sec
0.1sec
0.5sec
0.1sec
60sec
0.1sec
60sec
0.1sec
F
Function Description
F001
Acceleration time
F002
Deceleration time
F006
Max. Frequency
F007
Min. Frequency
F008
Gate Close High Speed
F010
Terminals
F020
Reset Terminal Function
F026
Gate Open Low Speed
F027
Gate Close Low Speed
8
Setting Method
SET1 on + OPN Button
SET1 on + CLS Button
SET1 on + PED Button
SET1 on + STP Button
SET1 on + OSC Button
SET1 on + PEB Button
SET2 on + OPN Button
SET2 on + CLS Button
SET2 on + PED Button
SET2 on + PED Button
DIP2 on + OSC Button
DIP2 on + PEB Button
Setting Unit Note
Range
0-6550sec.
0-6550sec.
0-6550sec.
0-25sec.
0-6550sec.
0-25sec.
0-25sec
0-25sec
0-6550sec
0-25sec
0-6500sec
0-6500sec
4.0
Sec.
2.0
Sec.
60
Hz
0
Hz
35
Hz
1
6
15
Hz
15
Hz