Epson Ink Cartridge T048520 for use with Epson Stylus Photo R300, R300N, and RX500 Manuel - Sayfa 3

Yazıcı Aksesuarları Epson Ink Cartridge T048520 for use with Epson Stylus Photo R300, R300N, and RX500 için çevrimiçi göz atın veya pdf Manuel indirin. Epson Ink Cartridge T048520 for use with Epson Stylus Photo R300, R300N, and RX500 4 sayfaları. Ink cartridge for use with epson stylus photo r300, r300n, and rx500 printers

Explosive properties:
Oxidizing properties:
Vapor density:
Relative density:
Solubility in water:
Solubility in fat:
Partition coefficient:
Viscosity:
10.
Stability and Reactivity
Stability:
Hazardous polymerization:
Hazard decomposition products: None
Incompatible materials:
11.
Toxicology and Health Hazards
Routes Of Overexposure: Eye, skin, inhalation, and oral
Acute Health Hazards:
Overexposure of eye surface to ink may be mildly irritating
Overexposure of skin to ink contact may cause irritation and in some people swelling and redness
Intentional inhalation overexposure to ink vapors may result in respiratory tract irritation
Intentional or accidental oral ingestion may cause an upset stomach
Chronic Health Hazards:
Carcinogenicity:
Toxicity Data:
12.
Ecological Information
No data available on the adverse effects of this material on the environment
13.
Disposal Considerations
Used and unused cartridges are not a federal RCRA hazardous waste. Disposal should be in accordance with
federal, state, and local requirements.
14.
Transportation Information
Not regulated as a Hazardous Material by DOT, IMO, or IATA
15.
Regulatory Considerations
U.S. DOT Hazard Class Regulated?
U.S. OSHA Inhalation Hazard?
In U.S., NFPA/HMIS Hazard Rating:
EU RoHS compliant?
______________________________________________________________________________________________________
SDS # T048520
Page 3 of 4
None
None
Greater than 1 (air=1)
1.07 at 68 deg. F / 20 deg. C
Complete
No data available
No data available
Less than 5mPa-s
Stable
Will not occur
Oxidizers and explosives
None known
None known
Oral LD50
Dermal LD50
>5000mg/kg(Rats) >2000mg/kg(Rats) Not Applicable
NO
NO
Health (1), Flammability (1), Instability/Reactivity (0), Other (0)
YES
Inhalant LC50
OSHA Regulated?
Not Established
Release Date 7/01/13
Version 3.8 (USA)