diLUSSO CE920HSS Kurulum ve Kullanım Kılavuzu - Sayfa 6
Havalandırma Davlumbazı diLUSSO CE920HSS için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. diLUSSO CE920HSS 9 sayfaları. Concealed range hood
Ducted Mode: Ductwork Installation
Ductwork should be planned carefully before drilling and cutting the duct. Manufacturer suggests 150mm duct pipe for all
common ducting configurations, which is, duct into a ceiling cavity or roof space. In case this is in contradiction with any local
requirements and building codes, the installer must ensure that the product installation and connection complies with the local
and general regulation in force.
Ø150mm duct pipe is recommended, however, a reducer from Ø150mm to Ø120mm is provided should Ø120mm be
required.
Extra pipe and/or bends may be needed, depending on the length required and if there is any structure in the run e.g. rafters.
Recirculation Mode
This unit can be installed to operate in recirculation mode when ducting is not chosen. Ensure that the top ducting outlet is not
obstructed. Even a partial obstruction will restrict the range hood efficiency. When installed as recirculation mode, recommend
adding charcoal filters to range hood to operate in recirculation mode.
Page 6
Version 1.3
June 2018