Epson EMP-8100 İletişim Kılavuzu - Sayfa 8
Yazılım Epson EMP-8100 için çevrimiçi göz atın veya pdf İletişim Kılavuzu indirin. Epson EMP-8100 20 sayfaları. Esc/vp level 6 serial communication manual
Ayrıca Epson EMP-8100 için: Kullanım Kılavuzu (14 sayfalar), Teknik Özellikler (1 sayfalar)
(7) Parameters
: Parameters differ for each command, so refer the separate descriptions for each command.
* In the case of items for which the setting range can be adjusted, the parameter values are the values in the table below
which have been converted to hexadecimal format.
Table 5-8. Hexadecimal conversion list
Decimal
1
2
3
4
Hexadeci-
01
02
03
04
mal
Decimal
-1
-2
-3
-4
Hexadeci-
FF
FE
FD
FC
mal
* If a reply command contains an error attribute, the following parameter (2 bytes) is set.
Table 5-9. List of error parameters
Parameters
Network in use
0x0001
No applicable setting
0x0002
0x0003
Resource error
0x0004
Download in progress
0x0005
Setting not currently possible
0x0006
Lamp off
Error between projector and
0x0007
EasyMP.net
0x0008
EasyMP.net rebooting
0x0009
Status mismatch
Projector error
0x000A
Network not connected
0x000B
0x000C
Locked
0x000D
Not available for stack
(8) Checksum
: Represent checksum (1 byte)
Checksum calculation method
All bytes of data from the size to the parameters is added together, and the twos complement of the result in hexadecimal for-
mat is subtracted from 0x0100 to obtain the checksum.
Example) For the command "1D 0007 01 10 00 02 0A CS"
0x00 + 0x07 + 0x01 + 0x10 + 0x00 + 0x02 + 0x0A = 0x24 ---> 0x0100 - 0x24 = 0xDC
ESC/VP Level 6 Serial Communication Manual (Abridged Edition)
-30
-
E2
5
6
7
8
9
10
11
05
06
07
08
09
0A
0B
-5
-6
-7
-8
-9
-10
-11
FB
FA
F9
F8
F7
F6
F5
Error type
An attempt was made to communicate with the projector via a network connection, but
another computer was already communicating with the projector.
Parameter is outside the setting range and FromTo is incorrect.
Command is not supported, or unknown command.
Insufficient EasyMP.net resources.
Projector is in download mode.
The apply command received cannot be processed.
Projector lamp is switched off.
When the command was sent via EasyMP.net and too many retries or timeouts occur
between EasyMP.net and the projector, it indicates an error upstream from EasyMP.net.
EasyMP.net is at end sequence.
A command which was different from the expected command was received.
When too many retries or timeouts occur between master and slave projectors when
connected in a stack, it indicates an error upstream from the master projector.
An attempt at communication with the computer (network) was made, but no computer
(network) exists.
An item which has been locked by the administrator (installer) was specified.
A command which cannot be used for a stack configuration was specified.
0
00
12
13
14
15
16
17
18
0C
0D
0E
0F
10
11
12
-12
-13
-14
-15
-16
-17
-18
F4
F3
F2
F1
F0
EF
EE
Error condition
8 of 20
30
+
1E
19
20
21
22
23
24
25
13
14
15
16
17
18
19
-19
-20
-21
-22
-23
-24
-25
ED
EC
EB
EA
E9
E8
E7
26
27
28
29
30
1A
1B
1C
1D
1E
-26
-27
-28
-29
-30
E6
E5
E4
E3
E2