MSI MSI-8000HD Operatör El Kitabı - Sayfa 24
Monitör MSI MSI-8000HD için çevrimiçi göz atın veya pdf Operatör El Kitabı indirin. MSI MSI-8000HD 48 sayfaları. Rf remote display
Press Simultaneously
Print
F2
RF
Configure
Network
CONFIGURE
NETWORK
Total # of RD's
Total RD's
(Remote Sensor
Devices)
Exit and Cancel Changes
Exit and Save/Back 1 Level
0
F1
Transmission Strength should be set to the lowest setting possible to
Note
achieve the transmission required. Both the scale/Dyna-Link and the 8000
should be set at the same transmission strength setting.
Setting
0
1
2
3
4
20
MSI-8000HD Operator's Manual
PRINT STRINGS
1= Current Wt
2= Net Wt
3= Gross Wt
4= Tare Wt
5= Total Wt
6= Total Count
7= Current Wt
8=
9= CR-LF ( )
Setup Strings
Print Control
Output Rate
Network ID
ScaleCore ID
RF Channel
Network ID
Transmission
Enter / Select
Scroll
F2
Figure 5-1. COMM Set Up Menu
RF Power
Level
10dBm
12dBm
14dBm
16dBm
18dBm
Table 5-1. Transmission Strength Settings
(Wt-Unit-Mode
(Wt-Unit-Net
(Wt-Unit-Grs
(Wt-Unit-Tare
(Wt-Unit-Total )
(#Samples-TCNT
(no units or mode
(Reserved)
RF
SETUP
Enable RF
.
Strength
Range 1-4
(default 1)
SUM REMOTE SENSOR DEVICES SETUP
Transmit
Current
137mA
Lowest Transmission Power
155mA
(default on 7300s and 8000s)
170mA
188mA
215mA
Print String Format
)
Number entry screen
)
)
)
)
)
PRINT
CONTROL
Print String Output Rate
Number entry screen
(0-65535 seconds)
Range 1-254, (20-30)
Range 12-23
Range 0 to 999999
Range 0 to 4
Sum all Remote Devices
Sum in Pairs
(requires 4 Remotes)
Sum in Pairs + Grand Total
Off, summing disabled
Note
Off
(default)
F key
On Stable Load
Continuous
Affects cont-
inuous mode
only
RF Network
Number entry
screens