Crownline IM-162 Kullanım Kılavuzu - Sayfa 6

Buz Yapıcı Crownline IM-162 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Crownline IM-162 16 sayfaları.

Crownline IM-162 Kullanım Kılavuzu
Operating Instructions:
Step 1. Open the lid and take out the ice basket to add appropriate water into water reservoir.
Note: The water poured into water reservoir should be lower than the water reservoir's MAX position. When
water volume goes beyond the max, please open the bottom water drain plug to drain the spare water out.
Then close the transparent lid.
Step 2. After power on, press POWER button to start the machine.
Step 3. Select the desired ice size, the default size of machine is large one.
Note: Please select the (S) when ambient temperature is below 15°c.When the ambient temperature is higher than
30°C, Large ice cube sizes are recommended.
Note: For the first three cycles, the ice may be small and irregular in size.
Note: When the ice collecting tray is full please remove the ice immediately, Do not allow the ice collecting tray to
overfill.
Cleaning & Use Guidance:
1.
Clean the inner liner, ice collecting tray, water box, ice shovel and evaporator frequently. When cleaning,unplug the
unit and remove the ice cubes. Use a diluted solution of water and vinegar to clean the inside and the outside surface
of the Ice maker. Do not spray Ice maker with chemicals or diluted agents such as acids, gasoline or oil. Rinse
thoroughly before starting.
2.
Keep ventilation openings in the appliance enclosure, or in the built-in structure, clear of obstruction. Do not use
mechanical devices or other means to accelerate the defrosting process, other than those recommended by the
manufacturer.
3.
Reuse the machine after being idled for a period of time, it may not have enough water to pump for air retard, and
the indicator of "ADD WATER" will keep lighting. At this time, you just need to press POWER button again, the
machine can enter normal state.
4.
To ensure the cleanness of ice, please change water for water reservoir at least once one day. If do not use for a long
time, please drain the water out and clean it up.
5.
If the compressor takes a strike action for shortage water, fully water or interruption of power supply, it will delay
for 3mins to start up after restarted.
6.
Always use fresh water before starting ice production either at initial installation or after a long shut-off period.