Fireplace Installation
materials before installation.
3. Store the fireplace in a safe,
dry and dust free location until
you are ready to install the
fireplace.

Wiring

WARNING: To reduce the risk
of fire, electric shock or injury to
persons, always use a licensed
electrician.
WARNING: Ensure that the
circuit on which the fireplace is to
be installed has the power cut off
at the service panel until installa-
tion is complete.
1. Carefully remove the electrical
cover bracket from the back of
the fireplace by removing the
three retaining screws. (Figure 2)
Wiring Diagram
SWITCH BOARD
LED STRIPS
(RGB) - MEDIA
DISPLAY / CONTROL BOARD
8
RELAY BOARD
LED STRIPS
(RGB) - FLAME
FLICKER MOTOR
M
THERMISTOR
AC/DC
ADAPTER
FLAME LED STRIPS (AMBER)
2. Leaving a minimum of 3 in.
(7.6 cm) of slack, route the
power supply through a cable
clamp (not included) and the
hole in the electrical cover
bracket.
3. Remove the two covers off of
the unit at the front to access
the wire connections. (Figure 3)
For 120V Installations
Use two conductor, non-metallic
sheath cable with ground wire
(3 wires total) for the incoming
power supply.
CAUTION: Use the appropri-
ate wire to meet local and
national electrical codes for
rated power consumption.
• Connect the L1 wire from the
M
BLOWER MOTOR
ELEMENTS
THERMAL
LED DRIVER
BOARDS
CUTOUT