Setting up your new heater
The controls
1
To operate the off-peak storage heating function there are two
simple controls located at the top right of the heater.
2
To commission a new heater set both the INPuT and
ouTPuT controls to 'MAX' and leave for a minimum of 48 hours.
After this period the controls should be adjusted for everyday use.
Please remember that any changes you make will take at least 24
hours to take effect.
IMPORTANT - The new materials in the heater are likely to
produce a smell for the first few days of operation.
Rooms must be well ventilated and persons with
respiratory complaints, young children or caged birds
must not remain in close proximity to the heater for a
minimum of the first 48 hours of the set-up period.
Multiple installations
If several new heaters have been installed it's recommended that
the set up (commissioning) is phased over several days.
Setting up your heater for normal use
'INPUT' energy control
The INPuT controls the amount of off-peak electricity – i.e. the
'charge', going into the heater at night, and therefore it controls how
much heat is stored within the heater ready for use the next day.
The more electricity that goes in, the more heat is stored and
available for use the following day.
The setting of the INPuT controls on these models automatically
determines the temperature of the room at the end of the
off-peak charge period.
This is measured by a temperature sensor on the heater which senses
both the temperature inside the heater and the room temperature.
once a comfortable INPuT setting has been found, the CXLS will
compensate for changes in weather conditions automatically.
Setting the INPUT control
3
The INPuT control should initially be set as shown.
During the day after the first charge period the comfort level
4
provided by the heater should be noted. If it is felt that the level of
heating is either too high or too low, then the INPuT control should
be adjusted slightly up or down as appropriate before the next
charge period. This process should be repeated each day until the
most acceptable comfort conditions are arrived at.
TIP The INPuT control can be left at the established comfort setting
and the heater will automatically vary the charge taken to maintain
the setting. BuT the actual setting will be influenced by the prevailing
weather conditions, the room size and insulation levels of your home.
The most suitable settings will be found by experience.