Marking the fixing positions
Slide the heater in to position in the plinth aperture with the
front edge just behind the line of the plinth.
Note: Ensure that flexible pipes are not kinked and that the
electrical cord is not in contact with hot surfaces.
Replace the plinth and bring the appliance forward so that
the front edge slightly projects through the plinth.
Position the grille in front of the heater and fix with two
screws (smaller screws).
Mark the eight fixing holes (two on each side, two on the top
and two on the bottom). Remove the grille and drill 2mm pilot
holes.
Mounting the heater in to the plinth
Make sure the heater is adequately supported and that the
air inlet slots are not obstructed. Fix the grille to the heater
and use the eight longer screws provided to secure the
heater to the plinth.
Operation
1.
Switch on the electricity supply to the heater
2.
Winter use for heating:
Set the Winter/Summer switch to (Winter position)
Select either low or boost fan speed on the changeover
switch depending on heat required.
3.
Turn ON the central heating system.
4.
As hot water reaches the heat exchanger the low limit.
Thermostat should cut in and the fan will start to operate
(set at 38ºC).
5.
Summer use – cool blow.
The hydronic base unit heater may be used in Summer to
provide air circulation without heat.
Set the winter / Summer switch to
and Choose between low
In this position the fan will run at the selected speed until
manually reset.
Winter/Summer switch
Boost/low speed switch
(Summer position),
or boost fan
speed.
Troubleshooting
Insufficient heat output from the heat exchanger may be
caused by:
Airlock in the heat exchanger – (ISOLATE FROM
ELECTRICAL SUPPLY)
Remove the grille and bleed the appliance as in the
Water Connections' section.
Hot water temperature too low – the boiler thermostat
may need increasing.
Bulk of the hot water circulating through the radiators –
rebalance by closing back lockshield valves on radiators
to increase water flow through the appliance.
Dirty heat exchanger.
Wiring Diagram
Fig. 5