Engineering Specifications and Advanced Functions for Developers
Aeon Labs Z-Stick Gen5 is a Z-Wave USB adapter. When it connects to a host controller (via USB), it enables
the host controller to take part in the Z-Wave Network. You can use the PC Controller application to control
your Z-Wave devices via its Serial API function, this greatly simplifies Z-Wave network installation.
The Z-Stick Gen5 is also device firmware upgradeable by the end consumer. This enables the product to
always have the latest Z-Wave protocol, capabilities and commands.
By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via
intermediary "listening" Z-Wave products. Products that are Z-Wave certified can be used and communicate
with other Z-Wave certified devices.
1. Technical Specifications
Up to 500 feet/150 metres outdoors in normal mode or 1310 feet/400
Operating distance:
metres outdoors in PA mode.
2. Familiarize Yourself with Your Z-Stick
2.1 Interface
3. Independence Mode and Serial API-Mode Functions
3.1 Function of Action Button
Button action
Press and hold
Reset Z-Stick to factory Default:
1. Unplug the Z-Stick from the USB connector.
20 seconds
2. Press and hold the Action Button for 20 seconds.
3. If holding time more than one second, the LED will become red, then blink faster and
faster. If holding time more than 20 seconds, the LED will become blue and stay solid for 2
seconds, it indicates reset success, otherwise please repeat step 2.
Note:
1. This procedure should only be used when the primary controller is inoperable.