Aeon Labs AEO HEM2-100A Hızlı Başlangıç Kılavuzu - Sayfa 7
Ölçüm Cihazları Aeon Labs AEO HEM2-100A için çevrimiçi göz atın veya pdf Hızlı Başlangıç Kılavuzu indirin. Aeon Labs AEO HEM2-100A 11 sayfaları. Z-wave clamp power meter 2nd generation - two clamps max. 100 ampere
Report type send in Reporting Group 1 (Parameter Number 101, Parameter Size 4) Defines the type of
report sent for the Reporting Group 1.
Value
1
Battery Report
2
MultiSensor Report for the whole device
4
Meter Report for Watt for the whole device
8
Meter Report for kWh for the whole device (Default)
256
Meter Report for Watt for clamp 1
512
Meter Report for Watt for clamp 2
1024
Meter Report for Watt for clamp 3
2048
Meter Report for kWh for clamp 1
4096
Meter Report for Watt for clamp 2
8192
Meter Report for kWh for clamp 3
Report Type send in Reporting Group 2 (Parameter Number 102, Parameter Size 4) Defines the type of
report sent for the Reporting Group 2.
Value
Description
1
Battery Report
2
MultiSensor Report for the whole device
4
Meter Report for Watt for the whole device
8
Meter Report for kWh for the whole device
256
Meter Report for Watt for clamp 1
512
Meter Report for Watt for clamp 2
1024
Meter Report for Watt for clamp 3
2048
Meter Report for kWh for clamp 1
4096
Meter Report for Watt for clamp 2
8192
Meter Report for kWh for clamp 3
(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 7
Description