Pioneer YPM-2106ZF Servis Kılavuzu - Sayfa 40

Araç Alıcısı Pioneer YPM-2106ZF için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Pioneer YPM-2106ZF 43 sayfaları. Cd players

Pioneer YPM-2106ZF Servis Kılavuzu
YPM-2306ZF
3. AUTOMATIC ADJUSTMENT FUNC-
TIONS
Every circuit adjustment on the CD-LSI of this system is
automated.
Every circuit adjustment is automatically implemented
when the disc is inserted or the CD mode is selected
from the source key. The following describes how the
adjustments are executed.
1) FZD Cancel Setting
This setting is used for executing the focus close opera-
tion without fail.
When power is turned on, the FE offset level is read and
a voltage opposite to this offset value is written to the
CRAM on the IC to cancel the offset. In this manner, the
FZD threshold level can be set to a constant value
(+240mV), thereby ensuring to meet one of the require-
ments for the IC to execute the focus close that "the
FZD signal is latched at high".
2) Automatic Adjustment of TE, FE and RF Offset
Using REFO as the reference, this function adjusts the
pre-amp TE, FE and RF offsets to the respective target
value when power is turned on (targets values of the
TE, FE and RF are 0, 0 and −1V, respectively).
The following is the adjustment procedure :
(1) Respective offset (LD off) is read by the microcom-
puter via the servo LSI.
(2) The microcomputer calculates the voltages to be
corrected from the read values, then sets them to
the specified field.
3) Automatic Adjustment of Tracking Balance (T.
BAL)
This adjustment is used for eliminating differences
between the pickup E and F channels outputs by adjust-
ing gain of the amplifier on the LSI. In the actual opera-
tion, the TE waveform is adjusted so that it may be ver-
tically symmetric with REFO.
The following is the adjustment procedure :
(1) Make sure the focus close is complete.
(2) Kick the lens in the radial direction to generate the
TE waveform.
(3) At this time, the microcomputer reads the TE signal
offset value (via the servo LSI) being calculated by
the LSI.
40
(4) The microcomputer determines if the read offset
value is positive, negative or zero.
If the offset value = 0, the adjustment is terminated.
If the offset value = A positive or negative value,
gain of the E and F channels amplifiers are modified
according the predetermined rule.
Then above steps (2) through (4) are repeated until the
"Offset value = 0" or "Specified limit count" is reached.
4) Automatic Adjustment of FE Bias
This adjustment is intended at maximizing the RFI level
by optimizing the focus point in-play. This adjustment
utilizes the phase difference between the RF waveform
3T level and the focus error signal when disturbance is
applied.
Since disturbance is applied to the focus loop, this
adjustment is designed to take place in the same timing
as the auto gain control (to be described later).
The following is the adjustment procedure :
(1) Disturbance is injected to the focus loop by the com-
mand from the microcomputer (within the servo
LSI).
(2) The LSI detects fluctuation of the RF signal 3T com-
ponent level.
(3) The LSI determines relationship between fluctuation
of the 3T component and the injected disturbance to
detect magnitude and direction of the off-focus
introduced.
(4) The microcomputer reads the detected results from
the LSI.
(5) The microcomputer calculates necessary correction,
then hands the calculated value to the bias adjust-
ment term set on the LSI.
This adjustment is repeated several times, as it is so
with the auto gain control, to ensure higher accuracy.