Pioneer YPM-2306ZFWL Servis Kılavuzu - Sayfa 21
Araç Alıcısı Pioneer YPM-2306ZFWL için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Pioneer YPM-2306ZFWL 43 sayfaları. Cd players
- New Test Mode
S-CD plays the same way as before.
If an error such as off focus, spindle unlocking, unreadable sub-code, or sound skipping occurs after setup, its
cause and time occurred (in absolute time) are displayed.
During setup, operational status of the control software (internal RAM: CPOINT) is displayed.
These displays and functions are prepared for enhancing aging in the servicing and efficiency of trouble analysis.
(1) Shifting to the New Test Mode
1 Turn on the current test mode by starting the reset from the key (it varies between the products).
2 Select S-CD for the source through the specified procedure including use of the [SOURCE] key, and inserting the
disc. Then, press the [Jump Mode Selector] key while maintaining the regulator turned off.
3 After the above operations, the new test mode remains on irrespective of whether the S-CD is turned on or off.
You can reset the new test mode by turning on the reset start.
* With some products, the new test mode can be reset through the same operations as that employed for shifting to
the STBY mode (while maintaining the Acc turned off).
(2) Key Correspondence
Key
(Example)
Power Off
1
To power on
(offset adjustment performed)
2
–
3
–
4
–
5
RF AMP gain switching
6
To power on
(offset adjustment not performed)
7
–
Note: Eject and CD on/off is performed in the same procedure as that for the normal mode.
(3) Cause of Error and Error Code
Code Class
Contents
40
Electricity
Off focus detected.
41
Electricity
Spindle unlocked.
42
Electricity
Sub-code unreadable.
43
Electricity
Sound skipping detected.
Note: Mechanical errors during aging are not displayed.
The error codes should be indicated in the same way as in the normal mode.
Test mode
Power On
To power off
FWD-Kick
REV-Kick
T.Close (AGC performed)
/parameter display switching
Parameter display switching
/T.BAL adjustment/T.Open
F.Close/RF AGC/F.T.AGC
F.Mode switching
/T.Close (no AGC)/Jump switching
Description and cause
FOK goes low.
→ Damages/stains on disc, vibrations or failure on servo.
FOK = Low continued for 50 msec.
→ Damages/stains on disc, vibrations or failure on servo.
Sub-code was unreadable for 50 msec.
→ Damages/stains on disc, vibrations or failure on servo.
Last address memory function was activated.
→ Damages/stains on disc, vibrations or failure on servo.
YPM-2306ZF
New test mode
In-play
Error Production
–
Time/Err.No. switching
FF/TR+
–
REV/TR-
–
Scan
–
Mode
–
–
–
Auto/Manu T.No./Time switching
21