Instruction manual DNDS Kompakt
Product variants of motion and standstill monitoring system
Equipment
Monitoring actuations
DNDS 1C
DNDS 1D
DNDS 1FA
DNDS 1GA
DNDS 2C
DNDS 2D
DNDS 2GA
to use only as reporting contact
Accessories
Equipment
DNIA
DNDA
Description of DNDS 1C, 1D, 1FA, 1GA, 2C, 2D and 2GA
The DNDS is enclosed in a 100mm housing and requires a supply voltage of 24 VDC.
Features:
DNDS 1C, 2C & DNDS 1FA:
for standstill monitoring one safety contacts (13
for motion monitoring one safety contacts (23
DNDS 1D, 2D, DNDS 1GA & 2GA:
for standstill monitoring two safety contacts (13
for motion monitoring two safety contacts (33
DNDS 1C, 1D, DNDS 2C & 2D:
Connections for PNP-proximity sensors or an encoder via a DNIA adaptor.
DNDS 1FA, DNDS 1GA & 2GA:
The encoder is connected via a DNDA Cable adaptor type DNDA.
Status indicators.
Programmable machine rpm setting.
The DNDS complies with the following safety requirements:
The circuit is redundant with built-in self-monitoring.
•
The safety function remains effective in the case of a component failure.
•
With every on-off cycle of the machine the relays are automatically tested to make sure they open and close
•
correctly.
Signals of encoder
Requirements of the encoder
Encoder signal: Rectangular with amplitude of 0.5-5 V or si-
•
ne/cosine signal with 0.5-5 VSS.
Encoder frequenzy ≤ ≤ ≤ ≤ 300KHz TTL, 200KHz Sin/Cos.
•
Encoder with high resistance outputs during malfunction.
•
2 tracks 90° out of phase, 2 signals per track that are 180° out
•
of phase
The signals of encoder are not allowed to be generate syntheti-
•
cally
Reaction times
The total reaction time is the sum of:
Reaction time of the motion monitor
•
De-energisation time of the output relay (<20ms).
•
Delay of de-energisation on any external switching devices.
•
The reaction time of the motion monitor decreases as the speed to be monitored increases (linear).
It measures at 5 Hz about 200 ms and at 800 Hz about 1 ms
Products: safety
technique
1
1
1
1
2
2
2
Equipment function
Adapter to the encoder
Cable adapter for the encoder
14) and one NC contact (11
24) and one NC contact (21
14 23
34 43
DNDS KOMPAKT
Version 04 / 2011.03.16
Outputs
STOP
13
14
23
24
13
14
23
24
13
14
23
24
13
14
23
24
24)
44), positive guided.
1V-5V TTL
A
A*
B
B*
SPEED
33
34
43
44
33
34
43
44
33
34
43
44
33
34
43
44
12)
22), positive guided.
1Vss
Sin
Sin*
Cos
Cos*