4 . Installation instructions
Sensing of bulky-solid materials in metal con-
tainers or tanks. The position of the sensor is
set so that it is approximately 10 mm from the
inner wall of a storage tank.
Fig. 1: Sensing bulk-solid materials in storage tanks
Sensing of moving objects on conveyor. The
distance of the sensor from moving objects is
set according to their size, shape and material
composition (approx. 1 to 8 mm).
Fig. 3: Sensing objects on a conveyor
Detection of liquid presence in the inter-wall space of double-walled storage tanks. The sensor is
suspended down into the inter-wall space on its own cable. For this application, we recommend
variant „B" with an extended cable terminal with the installation variant of a PVC hose for cable
protection.
Fig. 5: Use of CPS for indicating presence of liquid in the inter-wall space
5
Sensor is used for sensing leakages in an
interception tank. Leakage indication in de-
tention pits and boxes with "Plate holder
PD–24–1".
Fig. 2: Use of CPS for sensing leakages in an
Sensor application for level gauges and eye
sights. The maximum wall thickness in both
cases is up to 10 mm. A glass or plastic level
gauge (tube) must have an outer diameter of
at least 20 mm. The face of the sensor must
be touching the wall.
Fixing plastic strap
PD–24–1
Fig. 4: CPS sensor application for level gauges and
Intrinsically safe supply units
(NSSU, NDSU or NLCU)
PD–24–1
interception tank
eye sights
Distance crown DK–24
CPS–24