5. Installation and putting into operation
Please follow next 4 steps:
• Mechanical mounting
• Electrical connection
• Settings
- see chapter
6. Mechanical mounting
THE SENSOR TYPE GPLS – 25N – 0
•
is intended to point level detection on plastic or
glass and gauge-tubes.
•
The sensor is fixed to the gauge pipe or tube by
means of two plastic straps (2.5 mm width). The
cable should be vertically downwards oriented.
The maximum wall thickness of the tube depends
on the detected medium (see technical data), the
maximum is 8 mm.
THE SENSOR TYPE GPLS – 25N – 1
•
is intended to thru-wall level sensing of liquids in
plastic or glass vessels with flat walls.
•
The sensor is installed on a clean and degreased
surface of the vessel wall. The attachment is done
by doublesides adhesive layer. Orientation of the
sensor can be arbitrary. Maximum thickness of
the vessel wall depends on the detected medium
(see technical data), the maximum is 8 mm.
© Dinel, s.r.o.
GPLS-25
5
- see chapter
7
- see chapter
8
Plastic straps
4
5