Dinel ULM-53 series Kullanım Kılavuzu - Sayfa 4
Lazer Seviyesi Dinel ULM-53 series için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Dinel ULM-53 series 20 sayfaları. Ultrasonic level meters
Ayrıca Dinel ULM-53 series için: Kullanım Kılavuzu (20 sayfalar), Manuel (8 sayfalar), Manuel (6 sayfalar)
S
AFETY
All operations described in this instruction manual have to be carried out by trained personnel or by
an accredited person only. Installation, commissioning, operation and maintenance of the ultrasonic
level meters has to be carried out in accordance with this instruction manual; the provisions of
regulations in force regarding the installation of electrical equipment have to be adhered to.
Improper use, installation or set-up of the sensor can lead to crashes in the application, (overfi lling
of the tank or damage of system components).
The manufacturer is not responsible for improper use, loss of work caused by either direct or
indirect damage, and for expenses incurred at the time of installation or during the period of use
of the sensor.
Customer service must be carried out by the manufacturer exclusively.
M
EASURING PRINCIPLE
The ULM
ultrasonic level meters are compact measurement devices containing an ultrasonic
®
transmitter and an electronic module. Using an transmitter, level meters transmit the series of
ultrasonic pulses that spread towards the level surface. The transmitter recuperates refl ected
acoustic waves that are subsequently processed in the electronic module. Based on the period
during which the individual pulses spread towards the level and back, this period is averaged by
the electronics that performs temperature compensation and subsequently a conversion to an
output current (voltage).
R
ANGE OF APPLICATION
For continuous non-contact level measurement of liquids (water solutions, sewerage water, etc.),
mash and paste materials (sediments, sticks, resins etc.) in closed or open vessels, sumps, reser-
voirs and open channels. In case the level of bulk-solid materials is measured, the measurement
range is reduced.
All setting-up is done using two buttons positioned in the upper part of the sensor. The level meter
is equipped with optical state indication (STATE) and with a setting-up process (MENU). The level
meter can output current or voltage signals. They are manufactured in model versions for non-
explosive areas (N) and explosive areas (Xi).
F
EATURES OF VARIANTS
ULM–53_–02–_
ULM–53_–06–_
ULM –53_–10–_
ULM –53_–20–_
3
measuring range from 0.25 m to 2 m, plastic PVDF transmitter and plastic
body (PP+HDPE), process connection with thread G 1".
measuring range from 0.25 m to 6 m, plastic PVDF transmitter and plastic
body (PP+HDPE), process connection with thread G 1 ½".
measuring range from 0.5 m to 10 m, plastic PVDF transmitter and plastic
body (PP+HDPE), aluminium alloy ("Xi" version) or HDPE ("N" version)
fl ange.
measuring range from 0.5 m to 20 m, with plastic PVDF transmitter and
plastic body (PP+HDPE), aluminium alloy fl ange.
ULM–53