Aeotec Door / Window Sensor 7 Hızlı Başlangıç Kılavuzu - Sayfa 7
Aksesuarlar Aeotec Door / Window Sensor 7 için çevrimiçi göz atın veya pdf Hızlı Başlangıç Kılavuzu indirin. Aeotec Door / Window Sensor 7 11 sayfaları.
Ayrıca Aeotec Door / Window Sensor 7 için: Kullanıcı Kılavuzu (9 sayfalar), Kullanıcı Kılavuzu (9 sayfalar), Kullanıcı Kılavuzu (10 sayfalar)
1
2
Parameter 8: BASIC command value sent to 2nd Association Group on On event
This is the BASIC command value sent in case of On event.
Size: 1 Byte, Default Value: 255
Setting
0 - 99
255
Parameter 9: BASIC command value sent to 2nd Association Group on Off event
This is the BASIC command value sent in case of Off event.
Size: 1 Byte, Default Value: 0
Setting
0 - 99
255
Parameter 10: Time Delay of On command frame from 2nd Association Group
On command is sent after a delay defined in this parameter.
Size: 2 Byte, Default Value: 0
Setting
0 - 32400
Parameter 11: Time Delay of Off command frame from 2nd Association Group
Off command is sent after a delay defined in this parameter.
Size: 2 Byte, Default Value: 0
Setting
0 - 32400
Parameter 12: Delay of Tamper Alarm Cancellation
Time a tamper alarm is delayed.
Size: 2 Byte, Default Value: 0
Setting
0 - 32400
Parameter 13: Reporting Tamper Alarm Cancellation
This parameter defines if the alarm cancellation event is reported.
Size: 1 Byte, Default Value: 1
Off
On and Off
Description
Value
Value
Description
Value
Value
Description
seconds
Description
seconds
Description
seconds