Parameter #
Size
23
2
DEFAULT = 3600
30. Temperature Offset Value.
The current measuring temperature value can be offset by a + and - a value by this setting. The scale can be
decided by Parameter Number 14.
Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit)
Parameter
Size
Value
#
30
-200 -
2
200
DEFAULT = 0
Light Sensor controls.
22. Light Threshold Report
Change threshold value for change in light sensor to induce an automatic report for temperature sensor.
Scale: Lux
Parameter
Size Value Description
#
22
2
0
Disable Threshold Report for Temperature Sensor
Sets threshold for inducing automatic report using
1 -
a scale of
10000
0.1 * value = temperature threshold
DEFAULT = 100
24. Light automatic report based on time.
This parameter is configured the time interval for Light sensor report. This value is larger, the battery life is longer.
Parameter #
Size
24
2
DEFAULT = 3600
31. Light Sensor Offset Value.
The current measuring light intensity value can be offset by setting a add and minus a value by this setting.
https://aeotec.freshdesk.com/support/solutions/articles/6000195459-trisensor-user-guide-
Value
1-32767
Description
Offset Value.
Value
1-32767
TriSensor user guide. : Aeotec
Description
Automatic report set in seconds.
Description
Automatic report set in seconds.