Aeotec AEOEZW132 Manuel - Sayfa 3
Anahtar Aeotec AEOEZW132 için çevrimiçi göz atın veya pdf Manuel indirin. Aeotec AEOEZW132 10 sayfaları. Dual nano switch with power metering
7-11-2020
2. If inclusion still fails, check if both devices use the same frequency.
3. Remove all dead devices from associations. Otherwise you will see severe delays.
4. Never use sleeping battery devices without a central controller.
5. Dont poll FLIRS devices.
6. Make sure to have enough mains powered device to benefit from the meshing
Association - one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are
always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a 'Basic Set' Command.
Association Groups:
Group Number
1
2
3
4
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further
enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the
desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the
same logic applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 3: Current Overload Protection.
Output Load will be turned off automatically after 30 seconds and if the current overrun 1.5A.
Size: 1 Byte, Default Value: 1
Setting
0
1
Parameter 4: Overheat protection.
Output Load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 100 u2103.
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 20: Configure the output status after re-power on it.
Configure the output status after re-power on it.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW132
manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZW132
Maximum
Description
Nodes
5
Z-Wave Plus Lifeline.When the load state of Dual Nano Switch (turn on/off the load) is changed, the
Hail CC and Basic Report (configured by parameter 80) can be sent to the associated nodes in this
group.
5
Forward the Basic Set, Switch All, Scene Activation Set to associated nodes in Group 2 when the
Dual Nano Switch receives the Basic Set, Switch All, Scene Activation Set commands from main
controller. (E.g. Send/forward Basic Set to control the other nodes in association Group 2)
5
Send Basic Set (configured by parameter 81 ) to the associated nodes in Group 3 when the
external switch S1 is operated.Note: The Switch Mode of external switch S1 should be identified
successfully, which means that the value of Configuration parameter 120 should be non-zero, then
the Basic Set can be sent to the associated nodes in Group 3 via triggering the S1 switch.
5
Send Basic Set (configured by parameter 82) to the associated nodes in Group 4 when the external
switch S2 is operated.Note: The Switch Mode of external switch S2 should be identified
successfully, which means that the value of Configuration parameter 121 should be non-zero, then
the Basic Set can be sent to the associated nodes in Group 3 via triggering the S2 switch.
Description
Disable
Enable
Description
Disable
Enable
Description
Last status
Always on
Always off
3/10