Aeotec ZW175-B Kullanıcı Kılavuzu - Sayfa 8
Anahtar Aeotec ZW175-B için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Aeotec ZW175-B 8 sayfaları.
25.11.2019
If 0 is set to this parameter setting, this would completely disable timed reports. (Parameter 111 does not need to be set).
Parameter 111 - Timed report interval.
Reports the sensors set on Parameter 101.
Size = 4 Byte
Default Setting = 600
Value
Description
30 -
Interval set in seconds.
2592000
Parameter 255 - Factory reset.
This value can only be configured to reset default values of Smart Switch 7 parameter settings. This can also be used to
factory reset and remove it from your Z-Wave network.
Size = 4 Byte
Default Setting = N/A
Value
Description
0
Do nothing.
Any value
Reset Parameter
within 4
Settings to default
bytes.
settings.
0x55555555
Completely factory reset
or
and remove from
1431655765
network.
https://aeotec.freshdesk.com/support/solutions/articles/6000219911-smart-switch-7-user-guide-
Smart Switch 7 user guide : Aeotec Group
8/8